+ The aoe_deadsecs module parameter determines the maximum number of
+ seconds that the driver will wait for an AoE device to provide a
+ response to an AoE command. After aoe_deadsecs seconds have
+ elapsed, the AoE device will be marked as "down".
+
+ The aoe_maxout module parameter has a default of 128. This is the
+ maximum number of unresponded packets that will be sent to an AoE
+ target at one time.
+
+ The aoe_dyndevs module parameter defaults to 1, meaning that the
+ driver will assign a block device minor number to a discovered AoE
+ target based on the order of its discovery. With dynamic minor
+ device numbers in use, a greater range of AoE shelf and slot
+ addresses can be supported. Users with udev will never have to
+ think about minor numbers. Using aoe_dyndevs=0 allows device nodes
+ to be pre-created using a static minor-number scheme with the
+ aoe-mkshelf script in the aoetools.