]> Pileus Git - ~andy/linux/blob - drivers/staging/nvec/nvec_power.c
Merge tag 'for_3.7-fixes-pm' of git://git.kernel.org/pub/scm/linux/kernel/git/khilman...
[~andy/linux] / drivers / staging / nvec / nvec_power.c
1 /*
2  * nvec_power: power supply driver for a NVIDIA compliant embedded controller
3  *
4  * Copyright (C) 2011 The AC100 Kernel Team <ac100@lists.launchpad.net>
5  *
6  * Authors:  Ilya Petrov <ilya.muromec@gmail.com>
7  *           Marc Dietrich <marvin24@gmx.de>
8  *
9  * This file is subject to the terms and conditions of the GNU General Public
10  * License.  See the file "COPYING" in the main directory of this archive
11  * for more details.
12  *
13  */
14
15 #include <linux/module.h>
16 #include <linux/platform_device.h>
17 #include <linux/err.h>
18 #include <linux/power_supply.h>
19 #include <linux/slab.h>
20 #include <linux/workqueue.h>
21 #include <linux/delay.h>
22
23 #include "nvec.h"
24
25 struct nvec_power {
26         struct notifier_block notifier;
27         struct delayed_work poller;
28         struct nvec_chip *nvec;
29         int on;
30         int bat_present;
31         int bat_status;
32         int bat_voltage_now;
33         int bat_current_now;
34         int bat_current_avg;
35         int time_remain;
36         int charge_full_design;
37         int charge_last_full;
38         int critical_capacity;
39         int capacity_remain;
40         int bat_temperature;
41         int bat_cap;
42         int bat_type_enum;
43         char bat_manu[30];
44         char bat_model[30];
45         char bat_type[30];
46 };
47
48 enum {
49         SLOT_STATUS,
50         VOLTAGE,
51         TIME_REMAINING,
52         CURRENT,
53         AVERAGE_CURRENT,
54         AVERAGING_TIME_INTERVAL,
55         CAPACITY_REMAINING,
56         LAST_FULL_CHARGE_CAPACITY,
57         DESIGN_CAPACITY,
58         CRITICAL_CAPACITY,
59         TEMPERATURE,
60         MANUFACTURER,
61         MODEL,
62         TYPE,
63 };
64
65 enum {
66         AC,
67         BAT,
68 };
69
70 struct bat_response {
71         u8 event_type;
72         u8 length;
73         u8 sub_type;
74         u8 status;
75         /* payload */
76         union {
77                 char plc[30];
78                 u16 plu;
79                 s16 pls;
80         };
81 };
82
83 static struct power_supply nvec_bat_psy;
84 static struct power_supply nvec_psy;
85
86 static int nvec_power_notifier(struct notifier_block *nb,
87                                unsigned long event_type, void *data)
88 {
89         struct nvec_power *power =
90             container_of(nb, struct nvec_power, notifier);
91         struct bat_response *res = (struct bat_response *)data;
92
93         if (event_type != NVEC_SYS)
94                 return NOTIFY_DONE;
95
96         if (res->sub_type == 0) {
97                 if (power->on != res->plu) {
98                         power->on = res->plu;
99                         power_supply_changed(&nvec_psy);
100                 }
101                 return NOTIFY_STOP;
102         }
103         return NOTIFY_OK;
104 }
105
106 static const int bat_init[] = {
107         LAST_FULL_CHARGE_CAPACITY, DESIGN_CAPACITY, CRITICAL_CAPACITY,
108         MANUFACTURER, MODEL, TYPE,
109 };
110
111 static void get_bat_mfg_data(struct nvec_power *power)
112 {
113         int i;
114         char buf[] = { '\x02', '\x00' };
115
116         for (i = 0; i < ARRAY_SIZE(bat_init); i++) {
117                 buf[1] = bat_init[i];
118                 nvec_write_async(power->nvec, buf, 2);
119         }
120 }
121
122 static int nvec_power_bat_notifier(struct notifier_block *nb,
123                                    unsigned long event_type, void *data)
124 {
125         struct nvec_power *power =
126             container_of(nb, struct nvec_power, notifier);
127         struct bat_response *res = (struct bat_response *)data;
128         int status_changed = 0;
129
130         if (event_type != NVEC_BAT)
131                 return NOTIFY_DONE;
132
133         switch (res->sub_type) {
134         case SLOT_STATUS:
135                 if (res->plc[0] & 1) {
136                         if (power->bat_present == 0) {
137                                 status_changed = 1;
138                                 get_bat_mfg_data(power);
139                         }
140
141                         power->bat_present = 1;
142
143                         switch ((res->plc[0] >> 1) & 3) {
144                         case 0:
145                                 power->bat_status =
146                                     POWER_SUPPLY_STATUS_NOT_CHARGING;
147                                 break;
148                         case 1:
149                                 power->bat_status =
150                                     POWER_SUPPLY_STATUS_CHARGING;
151                                 break;
152                         case 2:
153                                 power->bat_status =
154                                     POWER_SUPPLY_STATUS_DISCHARGING;
155                                 break;
156                         default:
157                                 power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
158                         }
159                 } else {
160                         if (power->bat_present == 1)
161                                 status_changed = 1;
162
163                         power->bat_present = 0;
164                         power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN;
165                 }
166                 power->bat_cap = res->plc[1];
167                 if (status_changed)
168                         power_supply_changed(&nvec_bat_psy);
169                 break;
170         case VOLTAGE:
171                 power->bat_voltage_now = res->plu * 1000;
172                 break;
173         case TIME_REMAINING:
174                 power->time_remain = res->plu * 3600;
175                 break;
176         case CURRENT:
177                 power->bat_current_now = res->pls * 1000;
178                 break;
179         case AVERAGE_CURRENT:
180                 power->bat_current_avg = res->pls * 1000;
181                 break;
182         case CAPACITY_REMAINING:
183                 power->capacity_remain = res->plu * 1000;
184                 break;
185         case LAST_FULL_CHARGE_CAPACITY:
186                 power->charge_last_full = res->plu * 1000;
187                 break;
188         case DESIGN_CAPACITY:
189                 power->charge_full_design = res->plu * 1000;
190                 break;
191         case CRITICAL_CAPACITY:
192                 power->critical_capacity = res->plu * 1000;
193                 break;
194         case TEMPERATURE:
195                 power->bat_temperature = res->plu - 2732;
196                 break;
197         case MANUFACTURER:
198                 memcpy(power->bat_manu, &res->plc, res->length - 2);
199                 power->bat_model[res->length - 2] = '\0';
200                 break;
201         case MODEL:
202                 memcpy(power->bat_model, &res->plc, res->length - 2);
203                 power->bat_model[res->length - 2] = '\0';
204                 break;
205         case TYPE:
206                 memcpy(power->bat_type, &res->plc, res->length - 2);
207                 power->bat_type[res->length - 2] = '\0';
208                 /* this differs a little from the spec
209                    fill in more if you find some */
210                 if (!strncmp(power->bat_type, "Li", 30))
211                         power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_LION;
212                 else
213                         power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
214                 break;
215         default:
216                 return NOTIFY_STOP;
217         }
218
219         return NOTIFY_STOP;
220 }
221
222 static int nvec_power_get_property(struct power_supply *psy,
223                                    enum power_supply_property psp,
224                                    union power_supply_propval *val)
225 {
226         struct nvec_power *power = dev_get_drvdata(psy->dev->parent);
227         switch (psp) {
228         case POWER_SUPPLY_PROP_ONLINE:
229                 val->intval = power->on;
230                 break;
231         default:
232                 return -EINVAL;
233         }
234         return 0;
235 }
236
237 static int nvec_battery_get_property(struct power_supply *psy,
238                                      enum power_supply_property psp,
239                                      union power_supply_propval *val)
240 {
241         struct nvec_power *power = dev_get_drvdata(psy->dev->parent);
242
243         switch (psp) {
244         case POWER_SUPPLY_PROP_STATUS:
245                 val->intval = power->bat_status;
246                 break;
247         case POWER_SUPPLY_PROP_CAPACITY:
248                 val->intval = power->bat_cap;
249                 break;
250         case POWER_SUPPLY_PROP_PRESENT:
251                 val->intval = power->bat_present;
252                 break;
253         case POWER_SUPPLY_PROP_VOLTAGE_NOW:
254                 val->intval = power->bat_voltage_now;
255                 break;
256         case POWER_SUPPLY_PROP_CURRENT_NOW:
257                 val->intval = power->bat_current_now;
258                 break;
259         case POWER_SUPPLY_PROP_CURRENT_AVG:
260                 val->intval = power->bat_current_avg;
261                 break;
262         case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW:
263                 val->intval = power->time_remain;
264                 break;
265         case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
266                 val->intval = power->charge_full_design;
267                 break;
268         case POWER_SUPPLY_PROP_CHARGE_FULL:
269                 val->intval = power->charge_last_full;
270                 break;
271         case POWER_SUPPLY_PROP_CHARGE_EMPTY:
272                 val->intval = power->critical_capacity;
273                 break;
274         case POWER_SUPPLY_PROP_CHARGE_NOW:
275                 val->intval = power->capacity_remain;
276                 break;
277         case POWER_SUPPLY_PROP_TEMP:
278                 val->intval = power->bat_temperature;
279                 break;
280         case POWER_SUPPLY_PROP_MANUFACTURER:
281                 val->strval = power->bat_manu;
282                 break;
283         case POWER_SUPPLY_PROP_MODEL_NAME:
284                 val->strval = power->bat_model;
285                 break;
286         case POWER_SUPPLY_PROP_TECHNOLOGY:
287                 val->intval = power->bat_type_enum;
288                 break;
289         default:
290                 return -EINVAL;
291         }
292         return 0;
293 }
294
295 static enum power_supply_property nvec_power_props[] = {
296         POWER_SUPPLY_PROP_ONLINE,
297 };
298
299 static enum power_supply_property nvec_battery_props[] = {
300         POWER_SUPPLY_PROP_STATUS,
301         POWER_SUPPLY_PROP_PRESENT,
302         POWER_SUPPLY_PROP_CAPACITY,
303         POWER_SUPPLY_PROP_VOLTAGE_NOW,
304         POWER_SUPPLY_PROP_CURRENT_NOW,
305 #ifdef EC_FULL_DIAG
306         POWER_SUPPLY_PROP_CURRENT_AVG,
307         POWER_SUPPLY_PROP_TEMP,
308         POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW,
309 #endif
310         POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
311         POWER_SUPPLY_PROP_CHARGE_FULL,
312         POWER_SUPPLY_PROP_CHARGE_EMPTY,
313         POWER_SUPPLY_PROP_CHARGE_NOW,
314         POWER_SUPPLY_PROP_MANUFACTURER,
315         POWER_SUPPLY_PROP_MODEL_NAME,
316         POWER_SUPPLY_PROP_TECHNOLOGY,
317 };
318
319 static char *nvec_power_supplied_to[] = {
320         "battery",
321 };
322
323 static struct power_supply nvec_bat_psy = {
324         .name = "battery",
325         .type = POWER_SUPPLY_TYPE_BATTERY,
326         .properties = nvec_battery_props,
327         .num_properties = ARRAY_SIZE(nvec_battery_props),
328         .get_property = nvec_battery_get_property,
329 };
330
331 static struct power_supply nvec_psy = {
332         .name = "ac",
333         .type = POWER_SUPPLY_TYPE_MAINS,
334         .supplied_to = nvec_power_supplied_to,
335         .num_supplicants = ARRAY_SIZE(nvec_power_supplied_to),
336         .properties = nvec_power_props,
337         .num_properties = ARRAY_SIZE(nvec_power_props),
338         .get_property = nvec_power_get_property,
339 };
340
341 static int counter;
342 static int const bat_iter[] = {
343         SLOT_STATUS, VOLTAGE, CURRENT, CAPACITY_REMAINING,
344 #ifdef EC_FULL_DIAG
345         AVERAGE_CURRENT, TEMPERATURE, TIME_REMAINING,
346 #endif
347 };
348
349 static void nvec_power_poll(struct work_struct *work)
350 {
351         char buf[] = { '\x01', '\x00' };
352         struct nvec_power *power = container_of(work, struct nvec_power,
353                                                 poller.work);
354
355         if (counter >= ARRAY_SIZE(bat_iter))
356                 counter = 0;
357
358 /* AC status via sys req */
359         nvec_write_async(power->nvec, buf, 2);
360         msleep(100);
361
362 /* select a battery request function via round robin
363    doing it all at once seems to overload the power supply */
364         buf[0] = '\x02';        /* battery */
365         buf[1] = bat_iter[counter++];
366         nvec_write_async(power->nvec, buf, 2);
367
368         schedule_delayed_work(to_delayed_work(work), msecs_to_jiffies(5000));
369 };
370
371 static int __devinit nvec_power_probe(struct platform_device *pdev)
372 {
373         struct power_supply *psy;
374         struct nvec_power *power;
375         struct nvec_chip *nvec = dev_get_drvdata(pdev->dev.parent);
376
377         power = devm_kzalloc(&pdev->dev, sizeof(struct nvec_power), GFP_NOWAIT);
378         if (power == NULL)
379                 return -ENOMEM;
380
381         dev_set_drvdata(&pdev->dev, power);
382         power->nvec = nvec;
383
384         switch (pdev->id) {
385         case AC:
386                 psy = &nvec_psy;
387
388                 power->notifier.notifier_call = nvec_power_notifier;
389
390                 INIT_DELAYED_WORK(&power->poller, nvec_power_poll);
391                 schedule_delayed_work(&power->poller, msecs_to_jiffies(5000));
392                 break;
393         case BAT:
394                 psy = &nvec_bat_psy;
395
396                 power->notifier.notifier_call = nvec_power_bat_notifier;
397                 break;
398         default:
399                 return -ENODEV;
400         }
401
402         nvec_register_notifier(nvec, &power->notifier, NVEC_SYS);
403
404         if (pdev->id == BAT)
405                 get_bat_mfg_data(power);
406
407         return power_supply_register(&pdev->dev, psy);
408 }
409
410 static int __devexit nvec_power_remove(struct platform_device *pdev)
411 {
412         struct nvec_power *power = platform_get_drvdata(pdev);
413
414         cancel_delayed_work_sync(&power->poller);
415         switch (pdev->id) {
416         case AC:
417                 power_supply_unregister(&nvec_psy);
418                 break;
419         case BAT:
420                 power_supply_unregister(&nvec_bat_psy);
421         }
422
423         return 0;
424 }
425
426 static struct platform_driver nvec_power_driver = {
427         .probe = nvec_power_probe,
428         .remove = __devexit_p(nvec_power_remove),
429         .driver = {
430                    .name = "nvec-power",
431                    .owner = THIS_MODULE,
432                    }
433 };
434
435 module_platform_driver(nvec_power_driver);
436
437 MODULE_AUTHOR("Ilya Petrov <ilya.muromec@gmail.com>");
438 MODULE_LICENSE("GPL");
439 MODULE_DESCRIPTION("NVEC battery and AC driver");
440 MODULE_ALIAS("platform:nvec-power");