]> Pileus Git - ~andy/linux/blob - drivers/scsi/Kconfig
Merge tag 'nfs-for-3.6-2' of git://git.linux-nfs.org/projects/trondmy/linux-nfs
[~andy/linux] / drivers / scsi / Kconfig
1 menu "SCSI device support"
2
3 config SCSI_MOD
4        tristate
5        default y if SCSI=n || SCSI=y
6        default m if SCSI=m
7
8 config RAID_ATTRS
9         tristate "RAID Transport Class"
10         default n
11         depends on BLOCK
12         depends on SCSI_MOD
13         ---help---
14           Provides RAID
15
16 config SCSI
17         tristate "SCSI device support"
18         depends on BLOCK
19         select SCSI_DMA if HAS_DMA
20         ---help---
21           If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
22           any other SCSI device under Linux, say Y and make sure that you know
23           the name of your SCSI host adapter (the card inside your computer
24           that "speaks" the SCSI protocol, also called SCSI controller),
25           because you will be asked for it.
26
27           You also need to say Y here if you have a device which speaks
28           the SCSI protocol.  Examples of this include the parallel port
29           version of the IOMEGA ZIP drive, USB storage devices, Fibre
30           Channel, and FireWire storage.
31
32           To compile this driver as a module, choose M here and read
33           <file:Documentation/scsi/scsi.txt>.
34           The module will be called scsi_mod.
35
36           However, do not compile this as a module if your root file system
37           (the one containing the directory /) is located on a SCSI device.
38
39 config SCSI_DMA
40         bool
41         default n
42
43 config SCSI_TGT
44         tristate "SCSI target support"
45         depends on SCSI && EXPERIMENTAL
46         ---help---
47           If you want to use SCSI target mode drivers enable this option.
48           If you choose M, the module will be called scsi_tgt.
49
50 config SCSI_NETLINK
51         bool
52         default n
53         select NET
54
55 config SCSI_PROC_FS
56         bool "legacy /proc/scsi/ support"
57         depends on SCSI && PROC_FS
58         default y
59         ---help---
60           This option enables support for the various files in
61           /proc/scsi.  In Linux 2.6 this has been superseded by
62           files in sysfs but many legacy applications rely on this.
63
64           If unsure say Y.
65
66 comment "SCSI support type (disk, tape, CD-ROM)"
67         depends on SCSI
68
69 config BLK_DEV_SD
70         tristate "SCSI disk support"
71         depends on SCSI
72         select CRC_T10DIF if BLK_DEV_INTEGRITY
73         ---help---
74           If you want to use SCSI hard disks, Fibre Channel disks,
75           Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
76           USB storage or the SCSI or parallel port version of
77           the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
78           the Disk-HOWTO and the Multi-Disk-HOWTO, available from
79           <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
80           CD-ROMs.
81
82           To compile this driver as a module, choose M here and read
83           <file:Documentation/scsi/scsi.txt>.
84           The module will be called sd_mod.
85
86           Do not compile this driver as a module if your root file system
87           (the one containing the directory /) is located on a SCSI disk.
88           In this case, do not compile the driver for your SCSI host adapter
89           (below) as a module either.
90
91 config CHR_DEV_ST
92         tristate "SCSI tape support"
93         depends on SCSI
94         ---help---
95           If you want to use a SCSI tape drive under Linux, say Y and read the
96           SCSI-HOWTO, available from
97           <http://www.tldp.org/docs.html#howto>, and
98           <file:Documentation/scsi/st.txt> in the kernel source.  This is NOT
99           for SCSI CD-ROMs.
100
101           To compile this driver as a module, choose M here and read
102           <file:Documentation/scsi/scsi.txt>. The module will be called st.
103
104 config CHR_DEV_OSST
105         tristate "SCSI OnStream SC-x0 tape support"
106         depends on SCSI
107         ---help---
108           The OnStream SC-x0 SCSI tape drives cannot be driven by the
109           standard st driver, but instead need this special osst driver and
110           use the  /dev/osstX char device nodes (major 206).  Via usb-storage,
111           you may be able to drive the USB-x0 and DI-x0 drives as well.
112           Note that there is also a second generation of OnStream
113           tape drives (ADR-x0) that supports the standard SCSI-2 commands for
114           tapes (QIC-157) and can be driven by the standard driver st.
115           For more information, you may have a look at the SCSI-HOWTO
116           <http://www.tldp.org/docs.html#howto>  and
117           <file:Documentation/scsi/osst.txt>  in the kernel source.
118           More info on the OnStream driver may be found on
119           <http://sourceforge.net/projects/osst/>
120           Please also have a look at the standard st docu, as most of it
121           applies to osst as well.
122
123           To compile this driver as a module, choose M here and read
124           <file:Documentation/scsi/scsi.txt>. The module will be called osst.
125
126 config BLK_DEV_SR
127         tristate "SCSI CDROM support"
128         depends on SCSI
129         ---help---
130           If you want to use a CD or DVD drive attached to your computer
131           by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
132           and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
133
134           Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
135
136           To compile this driver as a module, choose M here and read
137           <file:Documentation/scsi/scsi.txt>.
138           The module will be called sr_mod.
139
140 config BLK_DEV_SR_VENDOR
141         bool "Enable vendor-specific extensions (for SCSI CDROM)"
142         depends on BLK_DEV_SR
143         help
144           This enables the usage of vendor specific SCSI commands. This is
145           required to support multisession CDs with old NEC/TOSHIBA cdrom
146           drives (and HP Writers). If you have such a drive and get the first
147           session only, try saying Y here; everybody else says N.
148
149 config CHR_DEV_SG
150         tristate "SCSI generic support"
151         depends on SCSI
152         ---help---
153           If you want to use SCSI scanners, synthesizers or CD-writers or just
154           about anything having "SCSI" in its name other than hard disks,
155           CD-ROMs or tapes, say Y here. These won't be supported by the kernel
156           directly, so you need some additional software which knows how to
157           talk to these devices using the SCSI protocol:
158
159           For scanners, look at SANE (<http://www.sane-project.org/>). For CD
160           writer software look at Cdrtools
161           (<http://cdrecord.berlios.de/private/cdrecord.html>)
162           and for burning a "disk at once": CDRDAO
163           (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
164           quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
165           For other devices, it's possible that you'll have to write the
166           driver software yourself. Please read the file
167           <file:Documentation/scsi/scsi-generic.txt> for more information.
168
169           To compile this driver as a module, choose M here and read
170           <file:Documentation/scsi/scsi.txt>. The module will be called sg.
171
172           If unsure, say N.
173
174 config CHR_DEV_SCH
175         tristate "SCSI media changer support"
176         depends on SCSI
177         ---help---
178           This is a driver for SCSI media changers.  Most common devices are
179           tape libraries and MOD/CDROM jukeboxes.  *Real* jukeboxes, you
180           don't need this for those tiny 6-slot cdrom changers.  Media
181           changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
182           If you have such hardware and want to use it with linux, say Y
183           here.  Check <file:Documentation/scsi/scsi-changer.txt> for details.
184         
185           If you want to compile this as a module ( = code which can be
186           inserted in and removed from the running kernel whenever you want),
187           say M here and read <file:Documentation/kbuild/modules.txt> and
188           <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
189           If unsure, say N.
190
191 config SCSI_ENCLOSURE
192         tristate "SCSI Enclosure Support"
193         depends on SCSI && ENCLOSURE_SERVICES
194         help
195           Enclosures are devices sitting on or in SCSI backplanes that
196           manage devices.  If you have a disk cage, the chances are that
197           it has an enclosure device.  Selecting this option will just allow
198           certain enclosure conditions to be reported and is not required.
199
200 config SCSI_MULTI_LUN
201         bool "Probe all LUNs on each SCSI device"
202         depends on SCSI
203         help
204           Some devices support more than one LUN (Logical Unit Number) in order
205           to allow access to several media, e.g. CD jukebox, USB card reader,
206           mobile phone in mass storage mode. This option forces the kernel to
207           probe for all LUNs by default. This setting can be overriden by
208           max_luns boot/module parameter. Note that this option does not affect
209           devices conforming to SCSI-3 or higher as they can explicitely report
210           their number of LUNs. It is safe to say Y here unless you have one of
211           those rare devices which reacts in an unexpected way when probed for
212           multiple LUNs.
213
214 config SCSI_CONSTANTS
215         bool "Verbose SCSI error reporting (kernel size +=12K)"
216         depends on SCSI
217         help
218           The error messages regarding your SCSI hardware will be easier to
219           understand if you say Y here; it will enlarge your kernel by about
220           12 KB. If in doubt, say Y.
221
222 config SCSI_LOGGING
223         bool "SCSI logging facility"
224         depends on SCSI
225         ---help---
226           This turns on a logging facility that can be used to debug a number
227           of SCSI related problems.
228
229           If you say Y here, no logging output will appear by default, but you
230           can enable logging by saying Y to "/proc file system support" and
231           "Sysctl support" below and executing the command
232
233           echo <bitmask> > /proc/sys/dev/scsi/logging_level
234
235           where <bitmask> is a four byte value representing the logging type
236           and logging level for each type of logging selected.
237
238           There are a number of logging types and you can find them in the
239           source at <file:drivers/scsi/scsi_logging.h>. The logging levels
240           are also described in that file and they determine the verbosity of
241           the logging for each logging type.
242
243           If you say N here, it may be harder to track down some types of SCSI
244           problems. If you say Y here your kernel will be somewhat larger, but
245           there should be no noticeable performance impact as long as you have
246           logging turned off.
247
248 config SCSI_SCAN_ASYNC
249         bool "Asynchronous SCSI scanning"
250         depends on SCSI
251         help
252           The SCSI subsystem can probe for devices while the rest of the
253           system continues booting, and even probe devices on different
254           busses in parallel, leading to a significant speed-up.
255
256           If you have built SCSI as modules, enabling this option can
257           be a problem as the devices may not have been found by the
258           time your system expects them to have been.  You can load the
259           scsi_wait_scan module to ensure that all scans have completed.
260           If you build your SCSI drivers into the kernel, then everything
261           will work fine if you say Y here.
262
263           You can override this choice by specifying "scsi_mod.scan=sync"
264           or async on the kernel's command line.
265
266 menu "SCSI Transports"
267         depends on SCSI
268
269 config SCSI_SPI_ATTRS
270         tristate "Parallel SCSI (SPI) Transport Attributes"
271         depends on SCSI
272         help
273           If you wish to export transport-specific information about
274           each attached SCSI device to sysfs, say Y.  Otherwise, say N.
275
276 config SCSI_FC_ATTRS
277         tristate "FiberChannel Transport Attributes"
278         depends on SCSI
279         select SCSI_NETLINK
280         help
281           If you wish to export transport-specific information about
282           each attached FiberChannel device to sysfs, say Y.
283           Otherwise, say N.
284
285 config SCSI_FC_TGT_ATTRS
286         bool "SCSI target support for FiberChannel Transport Attributes"
287         depends on SCSI_FC_ATTRS
288         depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
289         help
290                 If you want to use SCSI target mode drivers enable this option.
291
292 config SCSI_ISCSI_ATTRS
293         tristate "iSCSI Transport Attributes"
294         depends on SCSI && NET
295         select BLK_DEV_BSGLIB
296         help
297           If you wish to export transport-specific information about
298           each attached iSCSI device to sysfs, say Y.
299           Otherwise, say N.
300
301 config SCSI_SAS_ATTRS
302         tristate "SAS Transport Attributes"
303         depends on SCSI
304         select BLK_DEV_BSG
305         help
306           If you wish to export transport-specific information about
307           each attached SAS device to sysfs, say Y.
308
309 source "drivers/scsi/libsas/Kconfig"
310
311 config SCSI_SRP_ATTRS
312         tristate "SRP Transport Attributes"
313         depends on SCSI
314         help
315           If you wish to export transport-specific information about
316           each attached SRP device to sysfs, say Y.
317
318 config SCSI_SRP_TGT_ATTRS
319         bool "SCSI target support for SRP Transport Attributes"
320         depends on SCSI_SRP_ATTRS
321         depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
322         help
323                 If you want to use SCSI target mode drivers enable this option.
324
325 endmenu
326
327 menuconfig SCSI_LOWLEVEL
328         bool "SCSI low-level drivers"
329         depends on SCSI!=n
330         default y
331
332 if SCSI_LOWLEVEL && SCSI
333
334 config ISCSI_TCP
335         tristate "iSCSI Initiator over TCP/IP"
336         depends on SCSI && INET
337         select CRYPTO
338         select CRYPTO_MD5
339         select CRYPTO_CRC32C
340         select SCSI_ISCSI_ATTRS
341         help
342          The iSCSI Driver provides a host with the ability to access storage
343          through an IP network. The driver uses the iSCSI protocol to transport
344          SCSI requests and responses over a TCP/IP network between the host
345          (the "initiator") and "targets".  Architecturally, the iSCSI driver
346          combines with the host's TCP/IP stack, network drivers, and Network
347          Interface Card (NIC) to provide the same functions as a SCSI or a
348          Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
349
350          To compile this driver as a module, choose M here: the
351          module will be called iscsi_tcp.
352
353          The userspace component needed to initialize the driver, documentation,
354          and sample configuration files can be found here:
355
356          http://open-iscsi.org
357
358 config ISCSI_BOOT_SYSFS
359         tristate "iSCSI Boot Sysfs Interface"
360         default n
361         help
362           This option enables support for exposing iSCSI boot information
363           via sysfs to userspace. If you wish to export this information,
364           say Y. Otherwise, say N.
365
366 source "drivers/scsi/cxgbi/Kconfig"
367 source "drivers/scsi/bnx2i/Kconfig"
368 source "drivers/scsi/bnx2fc/Kconfig"
369 source "drivers/scsi/be2iscsi/Kconfig"
370
371 config SGIWD93_SCSI
372         tristate "SGI WD93C93 SCSI Driver"
373         depends on SGI_HAS_WD93 && SCSI
374         help
375           If you have a Western Digital WD93 SCSI controller on
376           an SGI MIPS system, say Y.  Otherwise, say N.
377
378 config BLK_DEV_3W_XXXX_RAID
379         tristate "3ware 5/6/7/8xxx ATA-RAID support"
380         depends on PCI && SCSI
381         help
382           3ware is the only hardware ATA-Raid product in Linux to date.
383           This card is 2,4, or 8 channel master mode support only.
384           SCSI support required!!!
385
386           <http://www.3ware.com/>
387
388           Please read the comments at the top of
389           <file:drivers/scsi/3w-xxxx.c>.
390
391 config SCSI_HPSA
392         tristate "HP Smart Array SCSI driver"
393         depends on PCI && SCSI
394         select CHECK_SIGNATURE
395         help
396           This driver supports HP Smart Array Controllers (circa 2009).
397           It is a SCSI alternative to the cciss driver, which is a block
398           driver.  Anyone wishing to use HP Smart Array controllers who
399           would prefer the devices be presented to linux as SCSI devices,
400           rather than as generic block devices should say Y here.
401
402 config SCSI_3W_9XXX
403         tristate "3ware 9xxx SATA-RAID support"
404         depends on PCI && SCSI
405         help
406           This driver supports the 9000 series 3ware SATA-RAID cards.
407
408           <http://www.amcc.com>
409
410           Please read the comments at the top of
411           <file:drivers/scsi/3w-9xxx.c>.
412
413 config SCSI_3W_SAS
414         tristate "3ware 97xx SAS/SATA-RAID support"
415         depends on PCI && SCSI
416         help
417           This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
418
419           <http://www.lsi.com>
420
421           Please read the comments at the top of
422           <file:drivers/scsi/3w-sas.c>.
423
424 config SCSI_7000FASST
425         tristate "7000FASST SCSI support"
426         depends on ISA && SCSI && ISA_DMA_API
427         select CHECK_SIGNATURE
428         help
429           This driver supports the Western Digital 7000 SCSI host adapter
430           family.  Some information is in the source:
431           <file:drivers/scsi/wd7000.c>.
432
433           To compile this driver as a module, choose M here: the
434           module will be called wd7000.
435
436 config SCSI_ACARD
437         tristate "ACARD SCSI support"
438         depends on PCI && SCSI
439         help
440           This driver supports the ACARD SCSI host adapter.
441           Support Chip <ATP870 ATP876 ATP880 ATP885>
442           To compile this driver as a module, choose M here: the
443           module will be called atp870u.
444
445 config SCSI_AHA152X
446         tristate "Adaptec AHA152X/2825 support"
447         depends on ISA && SCSI
448         select SCSI_SPI_ATTRS
449         select CHECK_SIGNATURE
450         ---help---
451           This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
452           SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
453           must be manually specified in this case.
454
455           It is explained in section 3.3 of the SCSI-HOWTO, available from
456           <http://www.tldp.org/docs.html#howto>. You might also want to
457           read the file <file:Documentation/scsi/aha152x.txt>.
458
459           To compile this driver as a module, choose M here: the
460           module will be called aha152x.
461
462 config SCSI_AHA1542
463         tristate "Adaptec AHA1542 support"
464         depends on ISA && SCSI && ISA_DMA_API
465         ---help---
466           This is support for a SCSI host adapter.  It is explained in section
467           3.4 of the SCSI-HOWTO, available from
468           <http://www.tldp.org/docs.html#howto>.  Note that Trantor was
469           purchased by Adaptec, and some former Trantor products are being
470           sold under the Adaptec name.  If it doesn't work out of the box, you
471           may have to change some settings in <file:drivers/scsi/aha1542.h>.
472
473           To compile this driver as a module, choose M here: the
474           module will be called aha1542.
475
476 config SCSI_AHA1740
477         tristate "Adaptec AHA1740 support"
478         depends on EISA && SCSI
479         ---help---
480           This is support for a SCSI host adapter.  It is explained in section
481           3.5 of the SCSI-HOWTO, available from
482           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
483           of the box, you may have to change some settings in
484           <file:drivers/scsi/aha1740.h>.
485
486           To compile this driver as a module, choose M here: the
487           module will be called aha1740.
488
489 config SCSI_AACRAID
490         tristate "Adaptec AACRAID support"
491         depends on SCSI && PCI
492         help
493           This driver supports a variety of Dell, HP, Adaptec, IBM and
494           ICP storage products. For a list of supported products, refer
495           to <file:Documentation/scsi/aacraid.txt>.
496
497           To compile this driver as a module, choose M here: the module
498           will be called aacraid.
499
500
501 source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
502
503 config SCSI_AIC7XXX_OLD
504         tristate "Adaptec AIC7xxx support (old driver)"
505         depends on (ISA || EISA || PCI ) && SCSI
506         help
507           WARNING This driver is an older aic7xxx driver and is no longer
508           under active development.  Adaptec, Inc. is writing a new driver to
509           take the place of this one, and it is recommended that whenever
510           possible, people should use the new Adaptec written driver instead
511           of this one.  This driver will eventually be phased out entirely.
512
513           This is support for the various aic7xxx based Adaptec SCSI
514           controllers. These include the 274x EISA cards; 284x VLB cards;
515           2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
516           motherboard based SCSI controllers from Adaptec. It does not support
517           the AAA-13x RAID controllers from Adaptec, nor will it likely ever
518           support them. It does not support the 2920 cards from Adaptec that
519           use the Future Domain SCSI controller chip. For those cards, you
520           need the "Future Domain 16xx SCSI support" driver.
521
522           In general, if the controller is based on an Adaptec SCSI controller
523           chip from the aic777x series or the aic78xx series, this driver
524           should work. The only exception is the 7810 which is specifically
525           not supported (that's the RAID controller chip on the AAA-13x
526           cards).
527
528           Note that the AHA2920 SCSI host adapter is *not* supported by this
529           driver; choose "Future Domain 16xx SCSI support" instead if you have
530           one of those.
531
532           Information on the configuration options for this controller can be
533           found by checking the help file for each of the available
534           configuration options. You should read
535           <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
536           contacting the maintainer with any questions.  The SCSI-HOWTO,
537           available from <http://www.tldp.org/docs.html#howto>, can also
538           be of great help.
539
540           To compile this driver as a module, choose M here: the
541           module will be called aic7xxx_old.
542
543 source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
544 source "drivers/scsi/aic94xx/Kconfig"
545 source "drivers/scsi/mvsas/Kconfig"
546
547 config SCSI_MVUMI
548         tristate "Marvell UMI driver"
549         depends on SCSI && PCI
550         help
551           Module for Marvell Universal Message Interface(UMI) driver
552
553           To compile this driver as a module, choose M here: the
554           module will be called mvumi.
555
556 config SCSI_DPT_I2O
557         tristate "Adaptec I2O RAID support "
558         depends on SCSI && PCI && VIRT_TO_BUS
559         help
560           This driver supports all of Adaptec's I2O based RAID controllers as 
561           well as the DPT SmartRaid V cards.  This is an Adaptec maintained
562           driver by Deanna Bonds.  See <file:Documentation/scsi/dpti.txt>.
563
564           To compile this driver as a module, choose M here: the
565           module will be called dpt_i2o.
566
567 config SCSI_ADVANSYS
568         tristate "AdvanSys SCSI support"
569         depends on SCSI && VIRT_TO_BUS
570         depends on ISA || EISA || PCI
571         help
572           This is a driver for all SCSI host adapters manufactured by
573           AdvanSys. It is documented in the kernel source in
574           <file:drivers/scsi/advansys.c>.
575
576           To compile this driver as a module, choose M here: the
577           module will be called advansys.
578
579 config SCSI_IN2000
580         tristate "Always IN2000 SCSI support"
581         depends on ISA && SCSI
582         help
583           This is support for an ISA bus SCSI host adapter.  You'll find more
584           information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
585           out of the box, you may have to change the jumpers for IRQ or
586           address selection.
587
588           To compile this driver as a module, choose M here: the
589           module will be called in2000.
590
591 config SCSI_ARCMSR
592         tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
593         depends on PCI && SCSI
594         help
595           This driver supports all of ARECA's SATA/SAS RAID controller cards.
596           This is an ARECA-maintained driver by Erich Chen.
597           If you have any problems, please mail to: <erich@areca.com.tw>.
598           Areca supports Linux RAID config tools.
599           Please link <http://www.areca.com.tw>
600
601           To compile this driver as a module, choose M here: the
602           module will be called arcmsr (modprobe arcmsr).
603
604 source "drivers/scsi/megaraid/Kconfig.megaraid"
605 source "drivers/scsi/mpt2sas/Kconfig"
606 source "drivers/scsi/ufs/Kconfig"
607
608 config SCSI_HPTIOP
609         tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
610         depends on SCSI && PCI
611         help
612           This option enables support for HighPoint RocketRAID 3xxx/4xxx
613           controllers.
614
615           To compile this driver as a module, choose M here; the module
616           will be called hptiop. If unsure, say N.
617
618 config SCSI_BUSLOGIC
619         tristate "BusLogic SCSI support"
620         depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
621         ---help---
622           This is support for BusLogic MultiMaster and FlashPoint SCSI Host
623           Adapters. Consult the SCSI-HOWTO, available from
624           <http://www.tldp.org/docs.html#howto>, and the files
625           <file:Documentation/scsi/BusLogic.txt> and
626           <file:Documentation/scsi/FlashPoint.txt> for more information.
627           Note that support for FlashPoint is only available for 32-bit
628           x86 configurations.
629
630           To compile this driver as a module, choose M here: the
631           module will be called BusLogic.
632
633 config SCSI_FLASHPOINT
634         bool "FlashPoint support"
635         depends on SCSI_BUSLOGIC && PCI && X86_32
636         help
637           This option allows you to add FlashPoint support to the
638           BusLogic SCSI driver. The FlashPoint SCCB Manager code is
639           substantial, so users of MultiMaster Host Adapters may not
640           wish to include it.
641
642 config VMWARE_PVSCSI
643         tristate "VMware PVSCSI driver support"
644         depends on PCI && SCSI && X86
645         help
646           This driver supports VMware's para virtualized SCSI HBA.
647           To compile this driver as a module, choose M here: the
648           module will be called vmw_pvscsi.
649
650 config HYPERV_STORAGE
651         tristate "Microsoft Hyper-V virtual storage driver"
652         depends on SCSI && HYPERV
653         default HYPERV
654         help
655           Select this option to enable the Hyper-V virtual storage driver.
656
657 config LIBFC
658         tristate "LibFC module"
659         select SCSI_FC_ATTRS
660         select CRC32
661         ---help---
662           Fibre Channel library module
663
664 config LIBFCOE
665         tristate "LibFCoE module"
666         select LIBFC
667         ---help---
668           Library for Fibre Channel over Ethernet module
669
670 config FCOE
671         tristate "FCoE module"
672         depends on PCI
673         select LIBFCOE
674         ---help---
675           Fibre Channel over Ethernet module
676
677 config FCOE_FNIC
678         tristate "Cisco FNIC Driver"
679         depends on PCI && X86
680         select LIBFCOE
681         help
682           This is support for the Cisco PCI-Express FCoE HBA.
683
684           To compile this driver as a module, choose M here and read
685           <file:Documentation/scsi/scsi.txt>.
686           The module will be called fnic.
687
688 config SCSI_DMX3191D
689         tristate "DMX3191D SCSI support"
690         depends on PCI && SCSI
691         select SCSI_SPI_ATTRS
692         help
693           This is support for Domex DMX3191D SCSI Host Adapters.
694
695           To compile this driver as a module, choose M here: the
696           module will be called dmx3191d.
697
698 config SCSI_DTC3280
699         tristate "DTC3180/3280 SCSI support"
700         depends on ISA && SCSI
701         select SCSI_SPI_ATTRS
702         select CHECK_SIGNATURE
703         help
704           This is support for DTC 3180/3280 SCSI Host Adapters.  Please read
705           the SCSI-HOWTO, available from
706           <http://www.tldp.org/docs.html#howto>, and the file
707           <file:Documentation/scsi/dtc3x80.txt>.
708
709           To compile this driver as a module, choose M here: the
710           module will be called dtc.
711
712 config SCSI_EATA
713         tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
714         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
715         ---help---
716           This driver supports all EATA/DMA-compliant SCSI host adapters.  DPT
717           ISA and all EISA I/O addresses are probed looking for the "EATA"
718           signature. The addresses of all the PCI SCSI controllers reported
719           by the PCI subsystem are probed as well.
720
721           You want to read the start of <file:drivers/scsi/eata.c> and the
722           SCSI-HOWTO, available from
723           <http://www.tldp.org/docs.html#howto>.
724
725           To compile this driver as a module, choose M here: the
726           module will be called eata.
727
728 config SCSI_EATA_TAGGED_QUEUE
729         bool "enable tagged command queueing"
730         depends on SCSI_EATA
731         help
732           This is a feature of SCSI-2 which improves performance: the host
733           adapter can send several SCSI commands to a device's queue even if
734           previous commands haven't finished yet.
735           This is equivalent to the "eata=tc:y" boot option.
736
737 config SCSI_EATA_LINKED_COMMANDS
738         bool "enable elevator sorting"
739         depends on SCSI_EATA
740         help
741           This option enables elevator sorting for all probed SCSI disks and
742           CD-ROMs. It definitely reduces the average seek distance when doing
743           random seeks, but this does not necessarily result in a noticeable
744           performance improvement: your mileage may vary...
745           This is equivalent to the "eata=lc:y" boot option.
746
747 config SCSI_EATA_MAX_TAGS
748         int "maximum number of queued commands"
749         depends on SCSI_EATA
750         default "16"
751         help
752           This specifies how many SCSI commands can be maximally queued for
753           each probed SCSI device. You should reduce the default value of 16
754           only if you have disks with buggy or limited tagged command support.
755           Minimum is 2 and maximum is 62. This value is also the window size
756           used by the elevator sorting option above. The effective value used
757           by the driver for each probed SCSI device is reported at boot time.
758           This is equivalent to the "eata=mq:8" boot option.
759
760 config SCSI_EATA_PIO
761         tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
762         depends on (ISA || EISA || PCI) && SCSI && BROKEN
763         ---help---
764           This driver supports all EATA-PIO protocol compliant SCSI Host
765           Adapters like the DPT PM2001 and the PM2012A.  EATA-DMA compliant
766           host adapters could also use this driver but are discouraged from
767           doing so, since this driver only supports hard disks and lacks
768           numerous features.  You might want to have a look at the SCSI-HOWTO,
769           available from <http://www.tldp.org/docs.html#howto>.
770
771           To compile this driver as a module, choose M here: the
772           module will be called eata_pio.
773
774 config SCSI_FUTURE_DOMAIN
775         tristate "Future Domain 16xx SCSI/AHA-2920A support"
776         depends on (ISA || PCI) && SCSI
777         select CHECK_SIGNATURE
778         ---help---
779           This is support for Future Domain's 16-bit SCSI host adapters
780           (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
781           other adapters based on the Future Domain chipsets (Quantum
782           ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
783           It is explained in section 3.7 of the SCSI-HOWTO, available from
784           <http://www.tldp.org/docs.html#howto>.
785
786           NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
787           and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
788           controller support"). This Future Domain driver works with the older
789           Adaptec AHA-2920A boards with a Future Domain chip on them.
790
791           To compile this driver as a module, choose M here: the
792           module will be called fdomain.
793
794 config SCSI_GDTH
795         tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
796         depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
797         ---help---
798           Formerly called GDT SCSI Disk Array Controller Support.
799
800           This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI) 
801           manufactured by Intel Corporation/ICP vortex GmbH. It is documented
802           in the kernel source in <file:drivers/scsi/gdth.c> and
803           <file:drivers/scsi/gdth.h>.
804
805           To compile this driver as a module, choose M here: the
806           module will be called gdth.
807
808 config SCSI_ISCI
809         tristate "Intel(R) C600 Series Chipset SAS Controller"
810         depends on PCI && SCSI
811         depends on X86
812         select SCSI_SAS_LIBSAS
813         ---help---
814           This driver supports the 6Gb/s SAS capabilities of the storage
815           control unit found in the Intel(R) C600 series chipset.
816
817 config SCSI_GENERIC_NCR5380
818         tristate "Generic NCR5380/53c400 SCSI PIO support"
819         depends on ISA && SCSI
820         select SCSI_SPI_ATTRS
821         ---help---
822           This is a driver for the old NCR 53c80 series of SCSI controllers
823           on boards using PIO. Most boards such as the Trantor T130 fit this
824           category, along with a large number of ISA 8bit controllers shipped
825           for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
826           you should select the specific driver for that card rather than
827           generic 5380 support.
828
829           It is explained in section 3.8 of the SCSI-HOWTO, available from
830           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
831           of the box, you may have to change some settings in
832           <file:drivers/scsi/g_NCR5380.h>.
833
834           To compile this driver as a module, choose M here: the
835           module will be called g_NCR5380.
836
837 config SCSI_GENERIC_NCR5380_MMIO
838         tristate "Generic NCR5380/53c400 SCSI MMIO support"
839         depends on ISA && SCSI
840         select SCSI_SPI_ATTRS
841         ---help---
842           This is a driver for the old NCR 53c80 series of SCSI controllers
843           on boards using memory mapped I/O. 
844           It is explained in section 3.8 of the SCSI-HOWTO, available from
845           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
846           of the box, you may have to change some settings in
847           <file:drivers/scsi/g_NCR5380.h>.
848
849           To compile this driver as a module, choose M here: the
850           module will be called g_NCR5380_mmio.
851
852 config SCSI_GENERIC_NCR53C400
853         bool "Enable NCR53c400 extensions"
854         depends on SCSI_GENERIC_NCR5380
855         help
856           This enables certain optimizations for the NCR53c400 SCSI cards.
857           You might as well try it out.  Note that this driver will only probe
858           for the Trantor T130B in its default configuration; you might have
859           to pass a command line option to the kernel at boot time if it does
860           not detect your card.  See the file
861           <file:Documentation/scsi/g_NCR5380.txt> for details.
862
863 config SCSI_IPS
864         tristate "IBM ServeRAID support"
865         depends on PCI && SCSI
866         ---help---
867           This is support for the IBM ServeRAID hardware RAID controllers.
868           See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
869           and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
870           for more information.  If this driver does not work correctly
871           without modification please contact the author by email at
872           <ipslinux@adaptec.com>.
873
874           To compile this driver as a module, choose M here: the
875           module will be called ips.
876
877 config SCSI_IBMVSCSI
878         tristate "IBM Virtual SCSI support"
879         depends on PPC_PSERIES
880         select SCSI_SRP_ATTRS
881         help
882           This is the IBM POWER Virtual SCSI Client
883
884           To compile this driver as a module, choose M here: the
885           module will be called ibmvscsic.
886
887 config SCSI_IBMVSCSIS
888         tristate "IBM Virtual SCSI Server support"
889         depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
890         help
891           This is the SRP target driver for IBM pSeries virtual environments.
892
893           The userspace component needed to initialize the driver and
894           documentation can be found:
895
896           http://stgt.berlios.de/
897
898           To compile this driver as a module, choose M here: the
899           module will be called ibmvstgt.
900
901 config SCSI_IBMVFC
902         tristate "IBM Virtual FC support"
903         depends on PPC_PSERIES && SCSI
904         select SCSI_FC_ATTRS
905         help
906           This is the IBM POWER Virtual FC Client
907
908           To compile this driver as a module, choose M here: the
909           module will be called ibmvfc.
910
911 config SCSI_IBMVFC_TRACE
912         bool "enable driver internal trace"
913         depends on SCSI_IBMVFC
914         default y
915         help
916           If you say Y here, the driver will trace all commands issued
917           to the adapter. Performance impact is minimal. Trace can be
918           dumped using /sys/class/scsi_host/hostXX/trace.
919
920 config SCSI_INITIO
921         tristate "Initio 9100U(W) support"
922         depends on PCI && SCSI
923         help
924           This is support for the Initio 91XXU(W) SCSI host adapter.  Please
925           read the SCSI-HOWTO, available from
926           <http://www.tldp.org/docs.html#howto>.
927
928           To compile this driver as a module, choose M here: the
929           module will be called initio.
930
931 config SCSI_INIA100
932         tristate "Initio INI-A100U2W support"
933         depends on PCI && SCSI
934         help
935           This is support for the Initio INI-A100U2W SCSI host adapter.
936           Please read the SCSI-HOWTO, available from
937           <http://www.tldp.org/docs.html#howto>.
938
939           To compile this driver as a module, choose M here: the
940           module will be called a100u2w.
941
942 config SCSI_PPA
943         tristate "IOMEGA parallel port (ppa - older drives)"
944         depends on SCSI && PARPORT_PC
945         ---help---
946           This driver supports older versions of IOMEGA's parallel port ZIP
947           drive (a 100 MB removable media device).
948
949           Note that you can say N here if you have the SCSI version of the ZIP
950           drive: it will be supported automatically if you said Y to the
951           generic "SCSI disk support", above.
952
953           If you have the ZIP Plus drive or a more recent parallel port ZIP
954           drive (if the supplied cable with the drive is labeled "AutoDetect")
955           then you should say N here and Y to "IOMEGA parallel port (imm -
956           newer drives)", below.
957
958           For more information about this driver and how to use it you should
959           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
960           the SCSI-HOWTO, which is available from
961           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
962           you will still be able to use the parallel port for other tasks,
963           such as a printer; it is safe to compile both drivers into the
964           kernel.
965
966           To compile this driver as a module, choose M here: the
967           module will be called ppa.
968
969 config SCSI_IMM
970         tristate "IOMEGA parallel port (imm - newer drives)"
971         depends on SCSI && PARPORT_PC
972         ---help---
973           This driver supports newer versions of IOMEGA's parallel port ZIP
974           drive (a 100 MB removable media device).
975
976           Note that you can say N here if you have the SCSI version of the ZIP
977           drive: it will be supported automatically if you said Y to the
978           generic "SCSI disk support", above.
979
980           If you have the ZIP Plus drive or a more recent parallel port ZIP
981           drive (if the supplied cable with the drive is labeled "AutoDetect")
982           then you should say Y here; if you have an older ZIP drive, say N
983           here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
984
985           For more information about this driver and how to use it you should
986           read the file <file:Documentation/scsi/ppa.txt>.  You should also read
987           the SCSI-HOWTO, which is available from
988           <http://www.tldp.org/docs.html#howto>.  If you use this driver,
989           you will still be able to use the parallel port for other tasks,
990           such as a printer; it is safe to compile both drivers into the
991           kernel.
992
993           To compile this driver as a module, choose M here: the
994           module will be called imm.
995
996 config SCSI_IZIP_EPP16
997         bool "ppa/imm option - Use slow (but safe) EPP-16"
998         depends on SCSI_PPA || SCSI_IMM
999         ---help---
1000           EPP (Enhanced Parallel Port) is a standard for parallel ports which
1001           allows them to act as expansion buses that can handle up to 64
1002           peripheral devices.
1003
1004           Some parallel port chipsets are slower than their motherboard, and
1005           so we have to control the state of the chipset's FIFO queue every
1006           now and then to avoid data loss. This will be done if you say Y
1007           here.
1008
1009           Generally, saying Y is the safe option and slows things down a bit.
1010
1011 config SCSI_IZIP_SLOW_CTR
1012         bool "ppa/imm option - Assume slow parport control register"
1013         depends on SCSI_PPA || SCSI_IMM
1014         help
1015           Some parallel ports are known to have excessive delays between
1016           changing the parallel port control register and good data being
1017           available on the parallel port data/status register. This option
1018           forces a small delay (1.0 usec to be exact) after changing the
1019           control register to let things settle out. Enabling this option may
1020           result in a big drop in performance but some very old parallel ports
1021           (found in 386 vintage machines) will not work properly.
1022
1023           Generally, saying N is fine.
1024
1025 config SCSI_NCR53C406A
1026         tristate "NCR53c406a SCSI support"
1027         depends on ISA && SCSI
1028         help
1029           This is support for the NCR53c406a SCSI host adapter.  For user
1030           configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
1031           in the kernel source.  Also read the SCSI-HOWTO, available from
1032           <http://www.tldp.org/docs.html#howto>.
1033
1034           To compile this driver as a module, choose M here: the
1035           module will be called NCR53c406.
1036
1037 config SCSI_NCR_D700
1038         tristate "NCR Dual 700 MCA SCSI support"
1039         depends on MCA && SCSI
1040         select SCSI_SPI_ATTRS
1041         help
1042           This is a driver for the MicroChannel Dual 700 card produced by
1043           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1044           tries to negotiate sync and uses tag command queueing.
1045
1046           Unless you have an NCR manufactured machine, the chances are that
1047           you do not have this SCSI card, so say N.
1048
1049 config SCSI_LASI700
1050         tristate "HP Lasi SCSI support for 53c700/710"
1051         depends on GSC && SCSI
1052         select SCSI_SPI_ATTRS
1053         help
1054           This is a driver for the SCSI controller in the Lasi chip found in
1055           many PA-RISC workstations & servers.  If you do not know whether you
1056           have a Lasi chip, it is safe to say "Y" here.
1057
1058 config SCSI_SNI_53C710
1059         tristate "SNI RM SCSI support for 53c710"
1060         depends on SNI_RM && SCSI
1061         select SCSI_SPI_ATTRS
1062         select 53C700_LE_ON_BE
1063         help
1064           This is a driver for the onboard SCSI controller found in older
1065           SNI RM workstations & servers.
1066
1067 config 53C700_LE_ON_BE
1068         bool
1069         depends on SCSI_LASI700
1070         default y
1071
1072 config SCSI_STEX
1073         tristate "Promise SuperTrak EX Series support"
1074         depends on PCI && SCSI
1075         ---help---
1076           This driver supports Promise SuperTrak EX series storage controllers.
1077
1078           Promise provides Linux RAID configuration utility for these
1079           controllers. Please visit <http://www.promise.com> to download.
1080
1081           To compile this driver as a module, choose M here: the
1082           module will be called stex.
1083
1084 config 53C700_BE_BUS
1085         bool
1086         depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
1087         default y
1088
1089 config SCSI_SYM53C8XX_2
1090         tristate "SYM53C8XX Version 2 SCSI support"
1091         depends on PCI && SCSI
1092         select SCSI_SPI_ATTRS
1093         ---help---
1094           This driver supports the whole NCR53C8XX/SYM53C8XX family of
1095           PCI-SCSI controllers.  It also supports the subset of LSI53C10XX
1096           Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
1097           language.  It does not support LSI53C10XX Ultra-320 PCI-X SCSI
1098           controllers; you need to use the Fusion MPT driver for that.
1099
1100           Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
1101           information.
1102
1103 config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
1104         int "DMA addressing mode"
1105         depends on SCSI_SYM53C8XX_2
1106         default "1"
1107         ---help---
1108           This option only applies to PCI-SCSI chips that are PCI DAC
1109           capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
1110
1111           When set to 0, the driver will program the chip to only perform
1112           32-bit DMA.  When set to 1, the chip will be able to perform DMA
1113           to addresses up to 1TB.  When set to 2, the driver supports the
1114           full 64-bit DMA address range, but can only address 16 segments
1115           of 4 GB each.  This limits the total addressable range to 64 GB.
1116
1117           Most machines with less than 4GB of memory should use a setting
1118           of 0 for best performance.  If your machine has 4GB of memory
1119           or more, you should set this option to 1 (the default).
1120
1121           The still experimental value 2 (64 bit DMA addressing with 16
1122           x 4GB segments limitation) can be used on systems that require
1123           PCI address bits past bit 39 to be set for the addressing of
1124           memory using PCI DAC cycles.
1125
1126 config SCSI_SYM53C8XX_DEFAULT_TAGS
1127         int "Default tagged command queue depth"
1128         depends on SCSI_SYM53C8XX_2
1129         default "16"
1130         help
1131           This is the default value of the command queue depth the
1132           driver will announce to the generic SCSI layer for devices
1133           that support tagged command queueing. This value can be changed
1134           from the boot command line.  This is a soft limit that cannot
1135           exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
1136
1137 config SCSI_SYM53C8XX_MAX_TAGS
1138         int "Maximum number of queued commands"
1139         depends on SCSI_SYM53C8XX_2
1140         default "64"
1141         help
1142           This option allows you to specify the maximum number of commands
1143           that can be queued to any device, when tagged command queuing is
1144           possible. The driver supports up to 256 queued commands per device.
1145           This value is used as a compiled-in hard limit.
1146
1147 config SCSI_SYM53C8XX_MMIO
1148         bool "Use memory mapped IO"
1149         depends on SCSI_SYM53C8XX_2
1150         default y
1151         help
1152           Memory mapped IO is faster than Port IO.  Most people should
1153           answer Y here, but some machines may have problems.  If you have
1154           to answer N here, please report the problem to the maintainer.
1155
1156 config SCSI_IPR
1157         tristate "IBM Power Linux RAID adapter support"
1158         depends on PCI && SCSI && ATA
1159         select FW_LOADER
1160         ---help---
1161           This driver supports the IBM Power Linux family RAID adapters.
1162           This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
1163           as IBM iSeries 5702, 5703, 5709, and 570A.
1164
1165 config SCSI_IPR_TRACE
1166         bool "enable driver internal trace"
1167         depends on SCSI_IPR
1168         default y
1169         help
1170           If you say Y here, the driver will trace all commands issued
1171           to the adapter. Performance impact is minimal. Trace can be
1172           dumped using /sys/bus/class/scsi_host/hostXX/trace.
1173
1174 config SCSI_IPR_DUMP
1175         bool "enable adapter dump support"
1176         depends on SCSI_IPR
1177         default y
1178         help
1179           If you say Y here, the driver will support adapter crash dump.
1180           If you enable this support, the iprdump daemon can be used
1181           to capture adapter failure analysis information.
1182
1183 config SCSI_ZALON
1184         tristate "Zalon SCSI support"
1185         depends on GSC && SCSI
1186         select SCSI_SPI_ATTRS
1187         help
1188           The Zalon is a GSC/HSC bus interface chip that sits between the
1189           PA-RISC processor and the NCR 53c720 SCSI controller on C100,
1190           C110, J200, J210 and some D, K & R-class machines.  It's also
1191           used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
1192           Say Y here if you have one of these machines or cards.
1193
1194 config SCSI_NCR_Q720
1195         tristate "NCR Quad 720 MCA SCSI support"
1196         depends on MCA && SCSI
1197         select SCSI_SPI_ATTRS
1198         help
1199           This is a driver for the MicroChannel Quad 720 card produced by
1200           NCR and commonly used in 345x/35xx/4100 class machines.  It always
1201           tries to negotiate sync and uses tag command queueing.
1202
1203           Unless you have an NCR manufactured machine, the chances are that
1204           you do not have this SCSI card, so say N.
1205
1206 config SCSI_NCR53C8XX_DEFAULT_TAGS
1207         int "default tagged command queue depth"
1208         depends on SCSI_ZALON || SCSI_NCR_Q720
1209         default "8"
1210         ---help---
1211           "Tagged command queuing" is a feature of SCSI-2 which improves
1212           performance: the host adapter can send several SCSI commands to a
1213           device's queue even if previous commands haven't finished yet.
1214           Because the device is intelligent, it can optimize its operations
1215           (like head positioning) based on its own request queue. Some SCSI
1216           devices don't implement this properly; if you want to disable this
1217           feature, enter 0 or 1 here (it doesn't matter which).
1218
1219           The default value is 8 and should be supported by most hard disks.
1220           This value can be overridden from the boot command line using the
1221           'tags' option as follows (example):
1222           'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
1223           4, set queue depth to 16 for target 2 and target 3 on controller 0
1224           and set queue depth to 10 for target 0 / lun 2 on controller 1.
1225
1226           The normal answer therefore is to go with the default 8 and to use
1227           a boot command line option for devices that need to use a different
1228           command queue depth.
1229
1230           There is no safe option other than using good SCSI devices.
1231
1232 config SCSI_NCR53C8XX_MAX_TAGS
1233         int "maximum number of queued commands"
1234         depends on SCSI_ZALON || SCSI_NCR_Q720
1235         default "32"
1236         ---help---
1237           This option allows you to specify the maximum number of commands
1238           that can be queued to any device, when tagged command queuing is
1239           possible. The default value is 32. Minimum is 2, maximum is 64.
1240           Modern hard disks are able to support 64 tags and even more, but
1241           do not seem to be faster when more than 32 tags are being used.
1242
1243           So, the normal answer here is to go with the default value 32 unless
1244           you are using very large hard disks with large cache (>= 1 MB) that
1245           are able to take advantage of more than 32 tagged commands.
1246
1247           There is no safe option and the default answer is recommended.
1248
1249 config SCSI_NCR53C8XX_SYNC
1250         int "synchronous transfers frequency in MHz"
1251         depends on SCSI_ZALON || SCSI_NCR_Q720
1252         default "20"
1253         ---help---
1254           The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
1255           rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80.  The numbers
1256           are respectively the maximum data transfer rates in mega-transfers
1257           per second for each class.  For example, a FAST-20 Wide 16 device is
1258           able to transfer data at 20 million 16 bit packets per second for a
1259           total rate of 40 MB/s.
1260
1261           You may specify 0 if you want to only use asynchronous data
1262           transfers. This is the safest and slowest option. Otherwise, specify
1263           a value between 5 and 80, depending on the capability of your SCSI
1264           controller.  The higher the number, the faster the data transfer.
1265           Note that 80 should normally be ok since the driver decreases the
1266           value automatically according to the controller's capabilities.
1267
1268           Your answer to this question is ignored for controllers with NVRAM,
1269           since the driver will get this information from the user set-up.  It
1270           also can be overridden using a boot setup option, as follows
1271           (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
1272           for FAST-20 synchronous data transfer (20 mega-transfers per
1273           second).
1274
1275           The normal answer therefore is not to go with the default but to
1276           select the maximum value 80 allowing the driver to use the maximum
1277           value supported by each controller. If this causes problems with
1278           your SCSI devices, you should come back and decrease the value.
1279
1280           There is no safe option other than using good cabling, right
1281           terminations and SCSI conformant devices.
1282
1283 config SCSI_NCR53C8XX_NO_DISCONNECT
1284         bool "not allow targets to disconnect"
1285         depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
1286         help
1287           This option is only provided for safety if you suspect some SCSI
1288           device of yours to not support properly the target-disconnect
1289           feature. In that case, you would say Y here. In general however, to
1290           not allow targets to disconnect is not reasonable if there is more
1291           than 1 device on a SCSI bus. The normal answer therefore is N.
1292
1293 config SCSI_PAS16
1294         tristate "PAS16 SCSI support"
1295         depends on ISA && SCSI
1296         select SCSI_SPI_ATTRS
1297         ---help---
1298           This is support for a SCSI host adapter.  It is explained in section
1299           3.10 of the SCSI-HOWTO, available from
1300           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1301           of the box, you may have to change some settings in
1302           <file:drivers/scsi/pas16.h>.
1303
1304           To compile this driver as a module, choose M here: the
1305           module will be called pas16.
1306
1307 config SCSI_QLOGIC_FAS
1308         tristate "Qlogic FAS SCSI support"
1309         depends on ISA && SCSI
1310         ---help---
1311           This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
1312           FastSCSI! cards as well as any other card based on the FASXX chip
1313           (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
1314
1315           This driver does NOT support the PCI versions of these cards. The
1316           PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
1317           SCSI support"), below.
1318
1319           Information about this driver is contained in
1320           <file:Documentation/scsi/qlogicfas.txt>.  You should also read the
1321           SCSI-HOWTO, available from
1322           <http://www.tldp.org/docs.html#howto>.
1323
1324           To compile this driver as a module, choose M here: the
1325           module will be called qlogicfas.
1326
1327 config SCSI_QLOGIC_1280
1328         tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
1329         depends on PCI && SCSI
1330         help
1331           Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
1332
1333           To compile this driver as a module, choose M here: the
1334           module will be called qla1280.
1335
1336 config SCSI_QLOGICPTI
1337         tristate "PTI Qlogic, ISP Driver"
1338         depends on SBUS && SCSI
1339         help
1340           This driver supports SBUS SCSI controllers from PTI or QLogic. These
1341           controllers are known under Solaris as qpti and in the openprom as
1342           PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
1343           driven by a different driver.
1344
1345           To compile this driver as a module, choose M here: the
1346           module will be called qlogicpti.
1347
1348 source "drivers/scsi/qla2xxx/Kconfig"
1349 source "drivers/scsi/qla4xxx/Kconfig"
1350
1351 config SCSI_LPFC
1352         tristate "Emulex LightPulse Fibre Channel Support"
1353         depends on PCI && SCSI
1354         select SCSI_FC_ATTRS
1355         help
1356           This lpfc driver supports the Emulex LightPulse
1357           Family of Fibre Channel PCI host adapters.
1358
1359 config SCSI_LPFC_DEBUG_FS
1360         bool "Emulex LightPulse Fibre Channel debugfs Support"
1361         depends on SCSI_LPFC && DEBUG_FS
1362         help
1363           This makes debugging information from the lpfc driver
1364           available via the debugfs filesystem.
1365
1366 config SCSI_SIM710
1367         tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
1368         depends on (EISA || MCA) && SCSI
1369         select SCSI_SPI_ATTRS
1370         ---help---
1371           This driver is for NCR53c710 based SCSI host adapters.
1372
1373           It currently supports Compaq EISA cards and NCR MCA cards
1374
1375 config SCSI_SYM53C416
1376         tristate "Symbios 53c416 SCSI support"
1377         depends on ISA && SCSI
1378         ---help---
1379           This is support for the sym53c416 SCSI host adapter, the SCSI
1380           adapter that comes with some HP scanners. This driver requires that
1381           the sym53c416 is configured first using some sort of PnP
1382           configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
1383           are using isapnp then you need to compile this driver as a module
1384           and then load it using insmod after isapnp has run. The parameters
1385           of the configured card(s) should be passed to the driver. The format
1386           is:
1387
1388           insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
1389
1390           To compile this driver as a module, choose M here: the
1391           module will be called sym53c416.
1392
1393 config SCSI_DC395x
1394         tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
1395         depends on PCI && SCSI && EXPERIMENTAL
1396         ---help---
1397           This driver supports PCI SCSI host adapters based on the ASIC
1398           TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
1399
1400           This driver works, but is still in experimental status. So better
1401           have a bootable disk and a backup in case of emergency.
1402
1403           Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
1404
1405           To compile this driver as a module, choose M here: the
1406           module will be called dc395x.
1407
1408 config SCSI_DC390T
1409         tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
1410         depends on PCI && SCSI
1411         ---help---
1412           This driver supports PCI SCSI host adapters based on the Am53C974A
1413           chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
1414           PCscsi/PCnet (Am53/79C974) solutions.
1415
1416           Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
1417
1418           Note that this driver does NOT support Tekram DC390W/U/F, which are
1419           based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
1420
1421           To compile this driver as a module, choose M here: the
1422           module will be called tmscsim.
1423
1424 config SCSI_T128
1425         tristate "Trantor T128/T128F/T228 SCSI support"
1426         depends on ISA && SCSI
1427         select SCSI_SPI_ATTRS
1428         select CHECK_SIGNATURE
1429         ---help---
1430           This is support for a SCSI host adapter. It is explained in section
1431           3.11 of the SCSI-HOWTO, available from
1432           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1433           of the box, you may have to change some settings in
1434           <file:drivers/scsi/t128.h>.  Note that Trantor was purchased by
1435           Adaptec, and some former Trantor products are being sold under the
1436           Adaptec name.
1437
1438           To compile this driver as a module, choose M here: the
1439           module will be called t128.
1440
1441 config SCSI_U14_34F
1442         tristate "UltraStor 14F/34F support"
1443         depends on ISA && SCSI && ISA_DMA_API
1444         ---help---
1445           This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
1446           The source at <file:drivers/scsi/u14-34f.c> contains some
1447           information about this hardware.  If the driver doesn't work out of
1448           the box, you may have to change some settings in
1449           <file: drivers/scsi/u14-34f.c>.  Read the SCSI-HOWTO, available from
1450           <http://www.tldp.org/docs.html#howto>.  Note that there is also
1451           another driver for the same hardware: "UltraStor SCSI support",
1452           below.  You should say Y to both only if you want 24F support as
1453           well.
1454
1455           To compile this driver as a module, choose M here: the
1456           module will be called u14-34f.
1457
1458 config SCSI_U14_34F_TAGGED_QUEUE
1459         bool "enable tagged command queueing"
1460         depends on SCSI_U14_34F
1461         help
1462           This is a feature of SCSI-2 which improves performance: the host
1463           adapter can send several SCSI commands to a device's queue even if
1464           previous commands haven't finished yet.
1465           This is equivalent to the "u14-34f=tc:y" boot option.
1466
1467 config SCSI_U14_34F_LINKED_COMMANDS
1468         bool "enable elevator sorting"
1469         depends on SCSI_U14_34F
1470         help
1471           This option enables elevator sorting for all probed SCSI disks and
1472           CD-ROMs. It definitely reduces the average seek distance when doing
1473           random seeks, but this does not necessarily result in a noticeable
1474           performance improvement: your mileage may vary...
1475           This is equivalent to the "u14-34f=lc:y" boot option.
1476
1477 config SCSI_U14_34F_MAX_TAGS
1478         int "maximum number of queued commands"
1479         depends on SCSI_U14_34F
1480         default "8"
1481         help
1482           This specifies how many SCSI commands can be maximally queued for
1483           each probed SCSI device. You should reduce the default value of 8
1484           only if you have disks with buggy or limited tagged command support.
1485           Minimum is 2 and maximum is 14. This value is also the window size
1486           used by the elevator sorting option above. The effective value used
1487           by the driver for each probed SCSI device is reported at boot time.
1488           This is equivalent to the "u14-34f=mq:8" boot option.
1489
1490 config SCSI_ULTRASTOR
1491         tristate "UltraStor SCSI support"
1492         depends on X86 && ISA && SCSI
1493         ---help---
1494           This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
1495           adapter family.  This driver is explained in section 3.12 of the
1496           SCSI-HOWTO, available from
1497           <http://www.tldp.org/docs.html#howto>.  If it doesn't work out
1498           of the box, you may have to change some settings in
1499           <file:drivers/scsi/ultrastor.h>.
1500
1501           Note that there is also another driver for the same hardware:
1502           "UltraStor 14F/34F support", above.
1503
1504           To compile this driver as a module, choose M here: the
1505           module will be called ultrastor.
1506
1507 config SCSI_NSP32
1508         tristate "Workbit NinjaSCSI-32Bi/UDE support"
1509         depends on PCI && SCSI && !64BIT
1510         help
1511           This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
1512           SCSI host adapter. Please read the SCSI-HOWTO, available from
1513           <http://www.tldp.org/docs.html#howto>.
1514
1515           To compile this driver as a module, choose M here: the
1516           module will be called nsp32.
1517
1518 config SCSI_DEBUG
1519         tristate "SCSI debugging host simulator"
1520         depends on SCSI
1521         select CRC_T10DIF
1522         help
1523           This is a host adapter simulator that can simulate multiple hosts
1524           each with multiple dummy SCSI devices (disks). It defaults to one
1525           host adapter with one dummy SCSI disk. Each dummy disk uses kernel
1526           RAM as storage (i.e. it is a ramdisk). To save space when multiple
1527           dummy disks are simulated, they share the same kernel RAM for 
1528           their storage. See <http://sg.danny.cz/sg/sdebug26.html> for more
1529           information. This driver is primarily of use to those testing the
1530           SCSI and block subsystems. If unsure, say N.
1531
1532 config SCSI_MESH
1533         tristate "MESH (Power Mac internal SCSI) support"
1534         depends on PPC32 && PPC_PMAC && SCSI
1535         help
1536           Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
1537           SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
1538           other Power Macintoshes do). Say Y to include support for this SCSI
1539           adaptor.
1540
1541           To compile this driver as a module, choose M here: the
1542           module will be called mesh.
1543
1544 config SCSI_MESH_SYNC_RATE
1545         int "maximum synchronous transfer rate (MB/s) (0 = async)"
1546         depends on SCSI_MESH
1547         default "5"
1548         help
1549           On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
1550           drives a bus which is entirely internal to the machine (such as the
1551           7500, 7600, 8500, etc.), the MESH is capable of synchronous
1552           operation at up to 10 MB/s. On machines where the SCSI bus
1553           controlled by the MESH can have external devices connected, it is
1554           usually rated at 5 MB/s. 5 is a safe value here unless you know the
1555           MESH SCSI bus is internal only; in that case you can say 10. Say 0
1556           to disable synchronous operation.
1557
1558 config SCSI_MESH_RESET_DELAY_MS
1559         int "initial bus reset delay (ms) (0 = no reset)"
1560         depends on SCSI_MESH
1561         default "4000"
1562
1563 config SCSI_MAC53C94
1564         tristate "53C94 (Power Mac external SCSI) support"
1565         depends on PPC32 && PPC_PMAC && SCSI
1566         help
1567           On Power Macintoshes (and clones) with two SCSI buses, the external
1568           SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
1569           machines which only have one SCSI bus, such as the 7200, also use
1570           the 53C94. Say Y to include support for the 53C94.
1571
1572           To compile this driver as a module, choose M here: the
1573           module will be called mac53c94.
1574
1575 source "drivers/scsi/arm/Kconfig"
1576
1577 config JAZZ_ESP
1578         bool "MIPS JAZZ FAS216 SCSI support"
1579         depends on MACH_JAZZ && SCSI
1580         select SCSI_SPI_ATTRS
1581         help
1582           This is the driver for the onboard SCSI host adapter of MIPS Magnum
1583           4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
1584           systems.
1585
1586 config A3000_SCSI
1587         tristate "A3000 WD33C93A support"
1588         depends on AMIGA && SCSI
1589         help
1590           If you have an Amiga 3000 and have SCSI devices connected to the
1591           built-in SCSI controller, say Y. Otherwise, say N.
1592
1593           To compile this driver as a module, choose M here: the
1594           module will be called a3000.
1595
1596 config A2091_SCSI
1597         tristate "A2091/A590 WD33C93A support"
1598         depends on ZORRO && SCSI
1599         help
1600           If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
1601           say N.
1602
1603           To compile this driver as a module, choose M here: the
1604           module will be called a2091.
1605
1606 config GVP11_SCSI
1607         tristate "GVP Series II WD33C93A support"
1608         depends on ZORRO && SCSI
1609         ---help---
1610           If you have a Great Valley Products Series II SCSI controller,
1611           answer Y. Also say Y if you have a later model of GVP SCSI
1612           controller (such as the GVP A4008 or a Combo board). Otherwise,
1613           answer N. This driver does NOT work for the T-Rex series of
1614           accelerators from TekMagic and GVP-M.
1615
1616           To compile this driver as a module, choose M here: the
1617           module will be called gvp11.
1618
1619 config SCSI_A4000T
1620         tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
1621         depends on AMIGA && SCSI && EXPERIMENTAL
1622         select SCSI_SPI_ATTRS
1623         help
1624           If you have an Amiga 4000T and have SCSI devices connected to the
1625           built-in SCSI controller, say Y. Otherwise, say N.
1626
1627           To compile this driver as a module, choose M here: the
1628           module will be called a4000t.
1629
1630 config SCSI_ZORRO7XX
1631         tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
1632         depends on ZORRO && SCSI && EXPERIMENTAL
1633         select SCSI_SPI_ATTRS
1634         help
1635           Support for various NCR53c710-based SCSI controllers on Zorro
1636           expansion boards for the Amiga.
1637           This includes:
1638             - the Amiga 4091 Zorro III SCSI-2 controller,
1639             - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
1640               (info at
1641               <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
1642             - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
1643               accelerator card for the Amiga 1200,
1644             - the SCSI controller on the GVP Turbo 040/060 accelerator.
1645
1646 config ATARI_SCSI
1647         tristate "Atari native SCSI support"
1648         depends on ATARI && SCSI
1649         select SCSI_SPI_ATTRS
1650         select NVRAM
1651         ---help---
1652           If you have an Atari with built-in NCR5380 SCSI controller (TT,
1653           Falcon, ...) say Y to get it supported. Of course also, if you have
1654           a compatible SCSI controller (e.g. for Medusa).
1655
1656           To compile this driver as a module, choose M here: the
1657           module will be called atari_scsi.
1658
1659           This driver supports both styles of NCR integration into the
1660           system: the TT style (separate DMA), and the Falcon style (via
1661           ST-DMA, replacing ACSI).  It does NOT support other schemes, like
1662           in the Hades (without DMA).
1663
1664 config ATARI_SCSI_TOSHIBA_DELAY
1665         bool "Long delays for Toshiba CD-ROMs"
1666         depends on ATARI_SCSI
1667         help
1668           This option increases the delay after a SCSI arbitration to
1669           accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
1670           use a Toshiba CD-ROM drive; otherwise, the option is not needed and
1671           would impact performance a bit, so say N.
1672
1673 config ATARI_SCSI_RESET_BOOT
1674         bool "Reset SCSI-devices at boottime"
1675         depends on ATARI_SCSI
1676         help
1677           Reset the devices on your Atari whenever it boots.  This makes the
1678           boot process fractionally longer but may assist recovery from errors
1679           that leave the devices with SCSI operations partway completed.
1680
1681 config MAC_SCSI
1682         bool "Macintosh NCR5380 SCSI"
1683         depends on MAC && SCSI=y
1684         select SCSI_SPI_ATTRS
1685         help
1686           This is the NCR 5380 SCSI controller included on most of the 68030
1687           based Macintoshes.  If you have one of these say Y and read the
1688           SCSI-HOWTO, available from
1689           <http://www.tldp.org/docs.html#howto>.
1690
1691 config SCSI_MAC_ESP
1692         tristate "Macintosh NCR53c9[46] SCSI"
1693         depends on MAC && SCSI
1694         select SCSI_SPI_ATTRS
1695         help
1696           This is the NCR 53c9x SCSI controller found on most of the 68040
1697           based Macintoshes.
1698
1699           To compile this driver as a module, choose M here: the module
1700           will be called mac_esp.
1701
1702 config MVME147_SCSI
1703         bool "WD33C93 SCSI driver for MVME147"
1704         depends on MVME147 && SCSI=y
1705         select SCSI_SPI_ATTRS
1706         help
1707           Support for the on-board SCSI controller on the Motorola MVME147
1708           single-board computer.
1709
1710 config MVME16x_SCSI
1711         tristate "NCR53C710 SCSI driver for MVME16x"
1712         depends on MVME16x && SCSI
1713         select SCSI_SPI_ATTRS
1714         help
1715           The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
1716           SCSI controller chip.  Almost everyone using one of these boards
1717           will want to say Y to this question.
1718
1719 config BVME6000_SCSI
1720         tristate "NCR53C710 SCSI driver for BVME6000"
1721         depends on BVME6000 && SCSI
1722         select SCSI_SPI_ATTRS
1723         help
1724           The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
1725           SCSI controller chip.  Almost everyone using one of these boards
1726           will want to say Y to this question.
1727
1728 config SUN3_SCSI
1729         tristate "Sun3 NCR5380 SCSI"
1730         depends on SUN3 && SCSI
1731         select SCSI_SPI_ATTRS
1732         help
1733           This option will enable support for the OBIO (onboard io) NCR5380
1734           SCSI controller found in the Sun 3/50 and 3/60, as well as for
1735           "Sun3" type VME scsi controllers also based on the NCR5380.
1736           General Linux information on the Sun 3 series (now discontinued)
1737           is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
1738
1739 config SUN3X_ESP
1740         bool "Sun3x ESP SCSI"
1741         depends on SUN3X && SCSI=y
1742         select SCSI_SPI_ATTRS
1743         help
1744           The ESP was an on-board SCSI controller used on Sun 3/80
1745           machines.  Say Y here to compile in support for it.
1746
1747 config SCSI_SUNESP
1748         tristate "Sparc ESP Scsi Driver"
1749         depends on SBUS && SCSI
1750         select SCSI_SPI_ATTRS
1751         help
1752           This is the driver for the Sun ESP SCSI host adapter. The ESP
1753           chipset is present in most SPARC SBUS-based computers and
1754           supports the Emulex family of ESP SCSI chips (esp100, esp100A,
1755           esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
1756
1757           To compile this driver as a module, choose M here: the
1758           module will be called sun_esp.
1759
1760 config ZFCP
1761         tristate "FCP host bus adapter driver for IBM eServer zSeries"
1762         depends on S390 && QDIO && SCSI
1763         select SCSI_FC_ATTRS
1764         help
1765           If you want to access SCSI devices attached to your IBM eServer
1766           zSeries by means of Fibre Channel interfaces say Y.
1767           For details please refer to the documentation provided by IBM at
1768           <http://oss.software.ibm.com/developerworks/opensource/linux390>
1769
1770           This driver is also available as a module. This module will be
1771           called zfcp. If you want to compile it as a module, say M here
1772           and read <file:Documentation/kbuild/modules.txt>.
1773
1774 config SCSI_PMCRAID
1775         tristate "PMC SIERRA Linux MaxRAID adapter support"
1776         depends on PCI && SCSI && NET
1777         ---help---
1778           This driver supports the PMC SIERRA MaxRAID adapters.
1779
1780 config SCSI_PM8001
1781         tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
1782         depends on PCI && SCSI
1783         select SCSI_SAS_LIBSAS
1784         help
1785           This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
1786           based host adapters.
1787
1788 config SCSI_SRP
1789         tristate "SCSI RDMA Protocol helper library"
1790         depends on SCSI && PCI
1791         select SCSI_TGT
1792         help
1793           If you wish to use SRP target drivers, say Y.
1794
1795           To compile this driver as a module, choose M here: the
1796           module will be called libsrp.
1797
1798 config SCSI_BFA_FC
1799         tristate "Brocade BFA Fibre Channel Support"
1800         depends on PCI && SCSI
1801         select SCSI_FC_ATTRS
1802         help
1803           This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
1804
1805           To compile this driver as a module, choose M here. The module will
1806           be called bfa.
1807
1808 config SCSI_VIRTIO
1809         tristate "virtio-scsi support (EXPERIMENTAL)"
1810         depends on EXPERIMENTAL && VIRTIO
1811         help
1812           This is the virtual HBA driver for virtio.  If the kernel will
1813           be used in a virtual machine, say Y or M.
1814
1815
1816 endif # SCSI_LOWLEVEL
1817
1818 source "drivers/scsi/pcmcia/Kconfig"
1819
1820 source "drivers/scsi/device_handler/Kconfig"
1821
1822 source "drivers/scsi/osd/Kconfig"
1823
1824 endmenu